◆ The central control system automatically or manually activates the solenoid valve to quickly release the water in the upper cavity of the deluge valve.
Product Description
◆ The KinFire deluge valve skid system for combined pressure control is suitable for the flow control of large fire protection systems. The system includes deluge valves with internal water diversion control pipelines (filters, ball valves, accelerator stop valves, etc.), upstream and downstream valves, bypass and test butterfly valves, anti-corrosive pipelines and frames. It can start the deluge valve by electricity, hydraulic pressure, air pressure, electricity-pneumatic signals and other control methods. When being opened, the valve reduces the upstream high pressure to a downstream pre-set low pressure, so that the flow rate conforms to the system design. It is widely used in ships, offshore drilling platforms, LNG, refineries and oil tank farms.
Operating Principle
◆ The central control system automatically or manually activates the solenoid valve to quickly release the water in the upper cavity of the deluge valve. The diaphragm is opened by the upstream pressure in the valve cavity, so that the deluge valve opens, and the water enters the fire-fighting water pipe network for spraying. When the fire alarm is lifted and it is needed to close the solenoid valve (if the solenoid valve has the manual reset function, the on-site manual reset can only be done after the safety is confirmed), the upstream water pressure enters the valve cavity through the pressure pipe, and the water pressure in the cavity increases to reset the diaphragm and close the deluge valve.
Features
Compact and reasonable pipeline layout |
Simple structure, easy to install and maintain |
Electric hydraulic and pneumatic control |
Unified junction box in the skid |
On-site and remote valve position indication |
Specially designed for seawater environment |
The whole system is pre-installed in the skid |
Adjustable spray water pressure |
On-site online repair |
Barrier-free full channel fluid design |
The whole skid is sprayed and anticorrosive |
Explosion-proof electrical parts |
Main Technical Parameter Table
Material of parts in contact with seawater |
Nickel aluminum bronze/monel |
Material of parts in no contact with seawater |
SS316 |
Pressure Level |
ANSI # 150 |
power supply |
24VDC |
Air pressure |
500 ~ 800KPag |
dangerous area |
Class l Division 1/Class l Division 2 |
size |
1½, 2, 2½, 3, 4, 6, 8, 10 & 12" |
Diaphragm |
NBR Nylon reinforced embedded solid |
Main Equipment List
◆ Each KinFire deluge valve skid system includes at least (but not limited to) the following:
Deluge valve |
1pcs |
Isolation valve |
1pcs |
Valve position indication |
1pcs |
Frame |
1pcs |
The electromagnetic valve |
1pcs |
Junction box |
1pcs |
Pipeline |
1pcs |
Pressure regulator |
1pcs |
Nameplate |
1pcs |
Control panel |
1pcs |
Pressure Transmitters |
1pcs |
Installation accessories |
1set |
Dimensions
Serial number |
model |
weight |
size |
flow |
1 | ZSFM80(FP-400E3 | 280Kg | 1300*450*1050mm | 136m³/h |
2 | ZSFM100(FP-400E4 | 420Kg | 1690*680*1300mm | 204m³/h |
3 | ZSFM150(FP-400E6 | 590Kg | 1940*800*1480mm | 458m³ / h |
4 | ZSFM200(FP-400E8 | 880Kg | 2366*800*1800mm | 781m³/h |
5 | ZSFM250(FP-400E10 | 1100Kg | 2740*950*1850mm | 829m³/h |
6 | ZSFM300(FP-400E12 | 1280Kg | 3210*1000*2130mm | 1932m³/h |
Certification And Standards
ABS, Lloyd's, CCC, UL, DNV, BV, FM, SO6182-5 fire and flame retardant test, NFPA American Fire Protection Association standards
KF-SC-DV-MA-S01
Since its establishment, KinFire Technology has a wide range of achievements in the fields of petrochemical...
CONTACT
ADDRESS:
520 Chang'an Road, Wujiang Economic and Technological Development Zone, Suzhou
BUSINESS:
Monday to Friday: 8:30 a.m. - 5:30 p.m
TELEPHONE:


IPHONE
Copyright KinFire Technology (Suzhou) Co., Ltd. © 2020 By www.300.cn 苏ICP备20025859号-1